Microarray Core Facility

Human Gene 2.0 ST Array

Each of the 40,719genes is represented on the array by approximately 26 probes spread across the full length of the gene, providing a more complete and more accurate picture of gene expression than 3’ based expression array designs.
The Gene 2.0 ST Array is part of a complete solution for gene expression analysis that includes Whole Transcript (WT) Sense Target Labeling and Control Reagents, fluidics and scanning instrumentation and basic analysis software. The array contains the most up-to-date content of well-annotated genes, and data is analyzed using a simple workflow.

The Gene 2.0 ST Array uses a subset of probes from the Human Exon 2.0 ST Array and covers only well-annotated content.

Human Gene 1.0 ST Annotation
Note: Annotation Files are intended for use in automated analysis. Some are not compatible with all spreadsheet applications.

In-Campus Chip Price : $205.00  (price may vary for off-campus customers)
In Stock

Please select services from the following list:

In-Campus-Price Product
$500.00 Affymetrix Array Two-round Amplification Full Service
Unit price per sample. This service start from small amount of total RNA.
$200.00 Affymetrix cRNA Probe Labeling
cRNA probe labeling only.
$250.00 Affymetrix Exon/ST Array Full Service
Start from total RNA, including probe labeling, hybridization, wash, stain, scanning and data collection.
$100.00 Affymetrix Exon/ST array hybridization
This service start from cRNA, including hybridization, wash, stain, scanning and data collection.
$40.00 Affymetrix GX Chip Scanning
Affymetrix chip scanning only.
$40.00 RNA/DNA Quality Check --Bioanalyzer Chip
$40 per chip, can process up to 12 samples if samples are in the range of 50-500 ng/ul (Nano Bioanalyzer Chip). Samples below 50 ng/ul will use Pico Bioanalyzer chip which holds 11 samples”. You must also order the service to complete this order
$5.00 Sample Quality Check Using Bioanalyzer Service
$5 per sample. Please submit RNA samples in the concentration range of 15 to 500 ng/ul for use with the Nano chip. Samples for microarray should be in the nanogram range for concentration. Bioanalyzer only orders with RNA samples below 15 ng/ul may use the Pico chip. An RNA Integrity Number (RIN) greater than 8.0 should be sufficient for microarray experiment. The starting tissue or cells should be freshly harvested and immediately frozen (snap frozen) in liquid nitrogen. Keep the samples on dry ice or liquid nitrogen before submitting to prevent thawing. Freshly dissected tissues may also be kept in Ambion RNAlater solution at RT or 4C. You must order a Bioanalyzer chip also to complete your order!
$50.00 Total RNA Extraction
Trizol and Qiagen RNeasy kit have been used to extract high-quality of total RNA. This service includes quality and quantity check.
Login To Order